COGO Smoke Escape Mask

A personal respiratory protective device with visor, hood and built-in filter for escape from fire. Protects against smoke and CO (Carbon Monoxide) inhalation. Complies with European Standard EN-403
Features
- Easy to use. Dons within seconds. No adjustments straps
- One size fits all
- Strong, fire-resistant, elastic rubber hood, protects the entire head and seals comfortably at the neck.
- Large visor, made of flame-retardant transparent film, allows a wide field of view
- A unique breathing device (patent pending), enables rapid exhalation and improves the physiological conditions for the user, preventing built-up of heat or vapor inside the mask
- A filtration unit containing low pressure electrostatic particle filter, impregnated charcoal cloth layers to absorb toxic gases and catalyst for Carbon Monoxide Oxidation. Training model available
Technical Data
Hood:
- Special Polychloroprene Latex compound
- Elongation at break: 700%
- Tensile strength: 150 kg/cm2
- Temperature resistant: 200°C
- Fire-resistant to the requirements of NFPA 701
Visor
ETFE film - a copolymer of Polytetrafluorethylene with Ethylene monomer.
- Tensile strength: 50 N/mm2
- Elongation at break: 450%
- Tear resistance: 500 N/mm
- Temperature resistance: 150°C
- Flame retardant: UL 94 V-O
- Light transmission: 95%
Breathing Device
- A device combining two valves for exhalation and inhalation + a soft mouthpiece, all in one unit
Filter Assembly
Two canisters containing:
- Electrostatic particle filter
- Layers of impregnated activated charcoal cloth
- Catalyst
- Desiccant
Filter Performance
Test Gas | Challenge Concentration (ml/m3) | Flow Rate (l/min) | Breakthrough Criteria (EN 403) | Breakthrough Time |
Propenal (Acrolein) | 100 | 30 | 15 min (at 0.5ml/m3) | 20 min |
Hidrogen Chloride (HCI) | 1000 | 30 | 15 min (at 5ml/m3) | 15 min |
Hidrogen Cayanide (HCN) | 400 | 30 | 15 min (at 10ml/m^3) | 15 min |
Carbon Monoxide (CO) | 10,000 | 30 | Total amount of CO penetrated during 15 min < 200 ml | 33 ml during 15 min |
Test | requirements (EN 403) | Test Results |
Particle filter penetration | 6 % | 1.3% |
Inhalation resistance | 8 mbar | 3.6 mbar |
Exhalation resistance | 3 mbar | 1.1 mbar |
CO2 content of inhalation air | 2.0% | 1.9% |
Protection factor | 50 | 50 |
General
- Approximate (package) dimensions: 19x15x10 cm
- Approximate (package) weight: 550 gr